 ## On this page

  

 

 # Joint condition: control using linear feedback

 Last update: 09.03.2026 

In this example, an existing load is modified to apply a torque proportional to the joint velocity. Two methods are discussed:

### Method 1

Obtain the velocity measure from the joint:

```
joint = CS_Joint.Find(_jid)
vel=joint.GetVelocity()

```

Next, modify an existing moment in order to use the velocity measure as its input measure:

```
Env=CS_Environment.FindFirstNonNull() 

ids=Env.DSToInternalIds[_jcid] 

load=CS_Actuator.Find(ids[0])
load.SetInputMeasure(vel)

```

### Method 2

Using this method, the load is created entirely using commands. These commands are shown below.

```
Env=CS_Environment.FindFirstNonNull() 

load=CS_JointDOFLoad(joint,0)
load.SetInputMeasure(vel)
load.SetFunc('0.1*(-2*acos(-1)-time)',0) 

Env.Loads.Add(load)

```