 ## On this page

  

 

 # sound:compute PR

 Last update: 31.07.2026 

**Version: 0.0.0**

## Description

Compute the Prominence Ratio (PR) according to the ECMA-418-1 (formerly ECMA-74, Annex D) and ISO7779:1999 standards, using a power spectral density (PSD) as input. This is applicable for tones whose frequencies are between 89.1 Hz and 11,220 Hz.

## Inputs

InputNameExpected type(s)Description**Pin 0**   
Requiredinput\_levels[`field`](../../core-concepts/dpf-types.md#field)Input PSD levels in ^2/Hz on which to compute PR, as a field. The PSD's frequencies must be regularly spaced. If the PSD's lowest frequency is not 0 Hz, values between 0 Hz and the PSD's lowest frequency are set to 0.**Pin 1**frequency\_list[`vector<double>`](../../core-concepts/dpf-types.md#standard-types)(Optional) list of the frequencies of the tones (peaks in the spectrum) for which to compute PR. If this input is empty (not specified), a peak detection method is applied to automatically find the tones in the input spectrum. Then, the PR is calculated for each detected tone.## Outputs

OutputNameExpected type(s)Description**Pin 0**output\_PR[`generic_data_container`](../../core-concepts/dpf-types.md#generic-data-container)Prominence Ratio data. This data container contains the final PR value (in dB), as well as the PR details for each specified frequency (if input frequency\_list is populated)or each detected tone (if input frequency\_list is omitted or empty). These details are stored in the class ansys::dpf\_sound::PsychoacousticIndicators\_PR\_results.Use the following identifiers to retrieve each piece of data:

- **PR\_max**: Maximum (final) PR value in dB, as a double
- **PR\_dB**: PR value in dB for each tone, as a field
- **frequency\_Hz**: Frequency of each tone in Hz, as a field
- **level\_dB**: Level of each tone in dB, as a field
- **bandwidth\_lower\_Hz**: Lower frequency in Hz of each tone's bandwidth, as a field
- **bandwidth\_higher\_Hz**: Upper frequency in Hz of each tone's bandwidth, as a field

The above data stored in the class PsychoacousticIndicators\_PR\_results can be accessed using the method GetProperty(property\_name) |

## Configurations

NameExpected type(s)Default valueDescription**mutex**[`bool`](../../core-concepts/dpf-types.md#standard-types)falseIf this option is set to true, the shared memory is prevented from being simultaneously accessed by multiple threads.## Scripting

**Category**: sound

**Plugin**: sound

**Scripting name**: None

**Full name**: None

**Internal name**: compute\_PR

**License**: avrxp\_snd\_level1

## Changelog

- Version 0.0.0: Initial release.