Skip to main content

Speos for NX library 2026 R1

SensorCommonBuilder

Last update: 24.03.2026

Full Name: SpeosNX_2512::SensorCommonBuilder

Language: Python

Inherits from: FeatureBuilder

Derived classes: SensorIntensityBuilder, SensorIrradianceBuilder, SensorRadianceBuilder

Description

A base class for all Sensor Builders.

A Builder is an object that is used to create and edit Features.

This is an abstract class that provides the basic functionality common to all builders. See the Builder subclasses for details of application-specific builders.

This is an abstract class, and cannot be instantiated.

Properties

thisown

public static

Defined in SpeosNX_2512.py at line 15611


Private Static Attributes

__repr__

private static

Defined in SpeosNX_2512.py at line 15615


Public Static Attributes

AxisSystem : str

public static

Gets the Axis System of the Sensor.

Value type: AxisSystem object.

Default value: = property(fget=__GetAxisSystem)

Defined in SpeosNX_2512.py at line 15783


DimensionFromFile : str

public static

Gets or sets the property to enable the use of dimensions that come from File.

True: Uses the following values from the XMP template: type, X and Y size, Wavelength values.

False: Does not use the dimension from file.

Value type: Boolean.

The default value is False.

Default value: = property(fget=__GetDimensionFromFile, fset=__SetDimensionFromFile)

Defined in SpeosNX_2512.py at line 15793


DisplayPropertiesFromFile : str

public static

Gets or sets the property to enable the use of display properties that come from File.

True: Uses all the grid related values from the .xml file.

False: Does not use the Display properties from file.

Value type: Boolean.

The default value is False.

Default value: = property(fget=__GetDisplayPropertiesFromFile, fset=__SetDisplayPropertiesFromFile)

Defined in SpeosNX_2512.py at line 15803


GridOriginX : str

public static

Gets or sets the grid X origin.

Value type: Double.

The default value is 0.0.

Default value: = property(fget=__GetGridOriginX, fset=__SetGridOriginX)

Defined in SpeosNX_2512.py at line 15810


GridOriginY : str

public static

Gets or sets the grid Y origin.

Value type: Double.

The default value is 0.0.

Default value: = property(fget=__GetGridOriginY, fset=__SetGridOriginY)

Defined in SpeosNX_2512.py at line 15817


GridStepX : str

public static

Gets or sets the grid X step.

Value type: Double.

Range: The value must be superior to 0.

The default value is 10.0.

Default value: = property(fget=__GetGridStepX, fset=__SetGridStepX)

Defined in SpeosNX_2512.py at line 15825


GridStepY : str

public static

Gets or sets the grid Y step.

Value type: Double.

Range: The value must be superior to 0.

The default value is 10.0.

Default value: = property(fget=__GetGridStepY, fset=__SetGridStepY)

Defined in SpeosNX_2512.py at line 15833


SensorFilter : str

public static

Gets the sensor filter.

Value type: SensorFilter object.

Default value: = property(fget=__GetSensorFilter)

Defined in SpeosNX_2512.py at line 15838


ShowGrid : str

public static

Gets or sets the property to enable grid preview.

True: Displays a grid on the sensor.

False: Does not display a grid on the sensor.

Value type: Boolean.

The default value is True.

Default value: = property(fget=__GetShowGrid, fset=__SetShowGrid)

Defined in SpeosNX_2512.py at line 15848


TemplateFilePath : str

public static

Gets or sets the template file's path.

Value type: String.

The default value is an empty string.

Default value: = property(fget=__GetTemplateFilePath, fset=__SetTemplateFilePath)

Defined in SpeosNX_2512.py at line 15855


TemplateType : str

public static

Gets or sets the template type.

The values are:

0 - None

1 - Measure

2 - Template

Value type: Integer.

The default value is 0.

Default value: = property(fget=__GetTemplateType)

Defined in SpeosNX_2512.py at line 15867


Type : str

public static

Gets or sets the type of the sensor.

The values are:

0 - Photometric, results in cd.

1 - Colorimetric, color results in cd or W/sr.

2 - Radiometric, results in W/sr.

3 - Spectral, results in cd or W/sr.

Value type: Integer.

The default value is 0.

Default value: = property(fget=__GetType, fset=__SetType)

Defined in SpeosNX_2512.py at line 15880


UseTemplateFile : str

public static

Gets or sets the property to enable the use of template file.

True: Enables Template File.

False: Disables Template File.

Value type: Boolean.

Default value: = property(fget=__GetUseTemplateFile, fset=__SetUseTemplateFile)

Defined in SpeosNX_2512.py at line 15888


WavelengthEnd : str

public static

Gets or sets the wavelength ending border.

Prerequisite: The Type property must be 1 or 3.

The sensor does not take account wavelengths beyond the borders that you define.

Value type: Double (in nm).

The default value is 700.0 nm.

Default value: = property(fget=__GetWavelengthEnd, fset=__SetWavelengthEnd)

Defined in SpeosNX_2512.py at line 15899


WavelengthResolution : str

public static

Gets or sets the Wavelength resolution.

Prerequisite: The Type property must be 1 or 3.

Value type: Double.

Default value: = property(fget=__GetWavelengthResolution, fset=__SetWavelengthResolution)

Defined in SpeosNX_2512.py at line 15906


WavelengthSampling : str

public static

Gets or sets the wavelength sampling.

Prerequisite: The Type property must be 1 or 3.

Value type: Integer.

Range: The value must be superior to 0.

The default value is 13.

Default value: = property(fget=__GetWavelengthSampling, fset=__SetWavelengthSampling)

Defined in SpeosNX_2512.py at line 15916


WavelengthStart : str

public static

Gets or sets the wavelength starting border.

Prerequisite: The Type property must be 1 or 3.

The sensor does not take account wavelengths beyond the borders that you define.

Value type: Double (in nm).

The default value is 400.0 nm.

Default value: = property(fget=__GetWavelengthStart, fset=__SetWavelengthStart)

Defined in SpeosNX_2512.py at line 15927


XEnd : str

public static

Gets or sets the Sensor X end dimension value.

Value type: Double (in mm).

The default value is 50.0 mm.

Default value: = property(fget=__GetXEnd, fset=__SetXEnd)

Defined in SpeosNX_2512.py at line 15934


XMirroredExtent : str

public static

Gets the Sensor X dimension mirrored extent value.

True: XStart == -XEnd, you can only change the XEnd value.

False: XStart and XEnd can have different value.

Value type: Boolean.

The default value is False.

Default value: = property(fget=__GetXMirroredExtent, fset=__SetXMirroredExtent)

Defined in SpeosNX_2512.py at line 15944


XResolution : str

public static

Gets or sets the Sensor X dimension resolution value.

Value type: Double.

Default value: = property(fget=__GetXResolution, fset=__SetXResolution)

Defined in SpeosNX_2512.py at line 15949


XSampling : str

public static

Gets or sets the Sensor X dimension sampling value.

Value type: Integer.

The default value is 100.

Default value: = property(fget=__GetXSampling, fset=__SetXSampling)

Defined in SpeosNX_2512.py at line 15956


XStart : str

public static

Gets or sets the Sensor X start dimension value.

Value type: Double (in mm).

The default value is -50.0 mm.

Default value: = property(fget=__GetXStart, fset=__SetXStart)

Defined in SpeosNX_2512.py at line 15963


YEnd : str

public static

Gets or sets the Sensor Y end dimension value.

Value type: Double (in mm).

The default value is 50.0 mm.

Default value: = property(fget=__GetYEnd, fset=__SetYEnd)

Defined in SpeosNX_2512.py at line 15970


YMirroredExtent : str

public static

Gets the Sensor Y dimension mirrored extent value.

True: YStart == -YEnd, you can only change the YEnd value.

False: YStart and YEnd can have different value.

Value type: Boolean.

The default value is False.

Default value: = property(fget=__GetYMirroredExtent, fset=__SetYMirroredExtent)

Defined in SpeosNX_2512.py at line 15980


YResolution : str

public static

Gets or sets the Sensor Y dimension resolution value.

Value type: Double.

Default value: = property(fget=__GetYResolution, fset=__SetYResolution)

Defined in SpeosNX_2512.py at line 15985


YSampling : str

public static

Gets or sets the Sensor Y dimension sampling value.

Value type: Integer.

The default value is 100.

Default value: = property(fget=__GetYSampling, fset=__SetYSampling)

Defined in SpeosNX_2512.py at line 15992


YStart : str

public static

Gets or sets the Sensor Y start dimension value.

Value type: Double (in mm).

The default value is -50.0 mm.

Default value: = property(fget=__GetYStart, fset=__SetYStart)

Defined in SpeosNX_2512.py at line 15999


Public Methods

IsTemplateFileValid(self)

public

Checks whether the template file is valid.

Returns: True: The template file is valid.

False: The template file is not valid.

Defined in SpeosNX_2512.py at line 15729


Member Summary

Member Type
AxisSystem public
DimensionFromFile public
DisplayPropertiesFromFile public
GridOriginX public
GridOriginY public
GridStepX public
GridStepY public
IsTemplateFileValid public
SensorFilter public
ShowGrid public
TemplateFilePath public
TemplateType public
Type public
UseTemplateFile public
WavelengthEnd public
WavelengthResolution public
WavelengthSampling public
WavelengthStart public
XEnd public
XMirroredExtent public
XResolution public
XSampling public
XStart public
YEnd public
YMirroredExtent public
YResolution public
YSampling public
YStart public
thisown public

Connect with Ansys