SensorCommonBuilder
Last update: 24.03.2026Full Name: SpeosNX_2512::SensorCommonBuilder
Language: Python
Inherits from: FeatureBuilder
Derived classes: SensorIntensityBuilder, SensorIrradianceBuilder, SensorRadianceBuilder
Description
A base class for all Sensor Builders.
A Builder is an object that is used to create and edit Features.
This is an abstract class that provides the basic functionality common to all builders. See the Builder subclasses for details of application-specific builders.
This is an abstract class, and cannot be instantiated.
Properties
thisown
public static
Defined in SpeosNX_2512.py at line 15611
Private Static Attributes
__repr__
private static
Defined in SpeosNX_2512.py at line 15615
Public Static Attributes
AxisSystem : str
public static
Gets the Axis System of the Sensor.
Value type: AxisSystem object.
Default value: = property(fget=__GetAxisSystem)
Defined in SpeosNX_2512.py at line 15783
DimensionFromFile : str
public static
Gets or sets the property to enable the use of dimensions that come from File.
True: Uses the following values from the XMP template: type, X and Y size, Wavelength values.
False: Does not use the dimension from file.
Value type: Boolean.
The default value is False.
Default value: = property(fget=__GetDimensionFromFile, fset=__SetDimensionFromFile)
Defined in SpeosNX_2512.py at line 15793
DisplayPropertiesFromFile : str
public static
Gets or sets the property to enable the use of display properties that come from File.
True: Uses all the grid related values from the .xml file.
False: Does not use the Display properties from file.
Value type: Boolean.
The default value is False.
Default value: = property(fget=__GetDisplayPropertiesFromFile, fset=__SetDisplayPropertiesFromFile)
Defined in SpeosNX_2512.py at line 15803
GridOriginX : str
public static
Gets or sets the grid X origin.
Value type: Double.
The default value is 0.0.
Default value: = property(fget=__GetGridOriginX, fset=__SetGridOriginX)
Defined in SpeosNX_2512.py at line 15810
GridOriginY : str
public static
Gets or sets the grid Y origin.
Value type: Double.
The default value is 0.0.
Default value: = property(fget=__GetGridOriginY, fset=__SetGridOriginY)
Defined in SpeosNX_2512.py at line 15817
GridStepX : str
public static
Gets or sets the grid X step.
Value type: Double.
Range: The value must be superior to 0.
The default value is 10.0.
Default value: = property(fget=__GetGridStepX, fset=__SetGridStepX)
Defined in SpeosNX_2512.py at line 15825
GridStepY : str
public static
Gets or sets the grid Y step.
Value type: Double.
Range: The value must be superior to 0.
The default value is 10.0.
Default value: = property(fget=__GetGridStepY, fset=__SetGridStepY)
Defined in SpeosNX_2512.py at line 15833
SensorFilter : str
public static
Gets the sensor filter.
Value type: SensorFilter object.
Default value: = property(fget=__GetSensorFilter)
Defined in SpeosNX_2512.py at line 15838
ShowGrid : str
public static
Gets or sets the property to enable grid preview.
True: Displays a grid on the sensor.
False: Does not display a grid on the sensor.
Value type: Boolean.
The default value is True.
Default value: = property(fget=__GetShowGrid, fset=__SetShowGrid)
Defined in SpeosNX_2512.py at line 15848
TemplateFilePath : str
public static
Gets or sets the template file's path.
Value type: String.
The default value is an empty string.
Default value: = property(fget=__GetTemplateFilePath, fset=__SetTemplateFilePath)
Defined in SpeosNX_2512.py at line 15855
TemplateType : str
public static
Gets or sets the template type.
The values are:
0 - None
1 - Measure
2 - Template
Value type: Integer.
The default value is 0.
Default value: = property(fget=__GetTemplateType)
Defined in SpeosNX_2512.py at line 15867
Type : str
public static
Gets or sets the type of the sensor.
The values are:
0 - Photometric, results in cd.
1 - Colorimetric, color results in cd or W/sr.
2 - Radiometric, results in W/sr.
3 - Spectral, results in cd or W/sr.
Value type: Integer.
The default value is 0.
Default value: = property(fget=__GetType, fset=__SetType)
Defined in SpeosNX_2512.py at line 15880
UseTemplateFile : str
public static
Gets or sets the property to enable the use of template file.
True: Enables Template File.
False: Disables Template File.
Value type: Boolean.
Default value: = property(fget=__GetUseTemplateFile, fset=__SetUseTemplateFile)
Defined in SpeosNX_2512.py at line 15888
WavelengthEnd : str
public static
Gets or sets the wavelength ending border.
Prerequisite: The Type property must be 1 or 3.
The sensor does not take account wavelengths beyond the borders that you define.
Value type: Double (in nm).
The default value is 700.0 nm.
Default value: = property(fget=__GetWavelengthEnd, fset=__SetWavelengthEnd)
Defined in SpeosNX_2512.py at line 15899
WavelengthResolution : str
public static
Gets or sets the Wavelength resolution.
Prerequisite: The Type property must be 1 or 3.
Value type: Double.
Default value: = property(fget=__GetWavelengthResolution, fset=__SetWavelengthResolution)
Defined in SpeosNX_2512.py at line 15906
WavelengthSampling : str
public static
Gets or sets the wavelength sampling.
Prerequisite: The Type property must be 1 or 3.
Value type: Integer.
Range: The value must be superior to 0.
The default value is 13.
Default value: = property(fget=__GetWavelengthSampling, fset=__SetWavelengthSampling)
Defined in SpeosNX_2512.py at line 15916
WavelengthStart : str
public static
Gets or sets the wavelength starting border.
Prerequisite: The Type property must be 1 or 3.
The sensor does not take account wavelengths beyond the borders that you define.
Value type: Double (in nm).
The default value is 400.0 nm.
Default value: = property(fget=__GetWavelengthStart, fset=__SetWavelengthStart)
Defined in SpeosNX_2512.py at line 15927
XEnd : str
public static
Gets or sets the Sensor X end dimension value.
Value type: Double (in mm).
The default value is 50.0 mm.
Default value: = property(fget=__GetXEnd, fset=__SetXEnd)
Defined in SpeosNX_2512.py at line 15934
XMirroredExtent : str
public static
Gets the Sensor X dimension mirrored extent value.
True: XStart == -XEnd, you can only change the XEnd value.
False: XStart and XEnd can have different value.
Value type: Boolean.
The default value is False.
Default value: = property(fget=__GetXMirroredExtent, fset=__SetXMirroredExtent)
Defined in SpeosNX_2512.py at line 15944
XResolution : str
public static
Gets or sets the Sensor X dimension resolution value.
Value type: Double.
Default value: = property(fget=__GetXResolution, fset=__SetXResolution)
Defined in SpeosNX_2512.py at line 15949
XSampling : str
public static
Gets or sets the Sensor X dimension sampling value.
Value type: Integer.
The default value is 100.
Default value: = property(fget=__GetXSampling, fset=__SetXSampling)
Defined in SpeosNX_2512.py at line 15956
XStart : str
public static
Gets or sets the Sensor X start dimension value.
Value type: Double (in mm).
The default value is -50.0 mm.
Default value: = property(fget=__GetXStart, fset=__SetXStart)
Defined in SpeosNX_2512.py at line 15963
YEnd : str
public static
Gets or sets the Sensor Y end dimension value.
Value type: Double (in mm).
The default value is 50.0 mm.
Default value: = property(fget=__GetYEnd, fset=__SetYEnd)
Defined in SpeosNX_2512.py at line 15970
YMirroredExtent : str
public static
Gets the Sensor Y dimension mirrored extent value.
True: YStart == -YEnd, you can only change the YEnd value.
False: YStart and YEnd can have different value.
Value type: Boolean.
The default value is False.
Default value: = property(fget=__GetYMirroredExtent, fset=__SetYMirroredExtent)
Defined in SpeosNX_2512.py at line 15980
YResolution : str
public static
Gets or sets the Sensor Y dimension resolution value.
Value type: Double.
Default value: = property(fget=__GetYResolution, fset=__SetYResolution)
Defined in SpeosNX_2512.py at line 15985
YSampling : str
public static
Gets or sets the Sensor Y dimension sampling value.
Value type: Integer.
The default value is 100.
Default value: = property(fget=__GetYSampling, fset=__SetYSampling)
Defined in SpeosNX_2512.py at line 15992
YStart : str
public static
Gets or sets the Sensor Y start dimension value.
Value type: Double (in mm).
The default value is -50.0 mm.
Default value: = property(fget=__GetYStart, fset=__SetYStart)
Defined in SpeosNX_2512.py at line 15999
Public Methods
IsTemplateFileValid(self)
public
Checks whether the template file is valid.
Returns: True: The template file is valid.
False: The template file is not valid.
Defined in SpeosNX_2512.py at line 15729
Member Summary
| Member | Type |
|---|---|
AxisSystem |
public |
DimensionFromFile |
public |
DisplayPropertiesFromFile |
public |
GridOriginX |
public |
GridOriginY |
public |
GridStepX |
public |
GridStepY |
public |
IsTemplateFileValid |
public |
SensorFilter |
public |
ShowGrid |
public |
TemplateFilePath |
public |
TemplateType |
public |
Type |
public |
UseTemplateFile |
public |
WavelengthEnd |
public |
WavelengthResolution |
public |
WavelengthSampling |
public |
WavelengthStart |
public |
XEnd |
public |
XMirroredExtent |
public |
XResolution |
public |
XSampling |
public |
XStart |
public |
YEnd |
public |
YMirroredExtent |
public |
YResolution |
public |
YSampling |
public |
YStart |
public |
thisown |