SensorLightFieldBuilder
Last update: 24.03.2026Full Name: SpeosNX_2512::SensorLightFieldBuilder
Language: Python
Inherits from: FeatureBuilder
Description
Represents a light field sensor builder.
The light field sensor builder creates or edits light field sensor features.
To create a new instance of this class, use FeatureCollection::CreateSensorLightFieldBuilder.
Properties
thisown
public static
Defined in SpeosNX_2512.py at line 17078
Private Static Attributes
__repr__
private static
Defined in SpeosNX_2512.py at line 17082
Public Static Attributes
ArrowLength : str
public static
Gets or sets the length of the arrow preview.
Value type: Double (in mm).
Range: The value must be superior to 0.0.
The default value is 10 mm.
Default value: = property(fget=__GetArrowLength, fset=__SetArrowLength)
Defined in SpeosNX_2512.py at line 17175
AxisSystem : str
public static
Gets the Axis System of the source.
Prerequisite: The CustomAxisSystem property must be True.
Value type: AxisSystem object.
Default value: = property(fget=__GetAxisSystem)
Defined in SpeosNX_2512.py at line 17182
AzimuthEnd : str
public static
Gets the azimuth end.
Value type: Double (in degree).
The default value is 360 deg.
Default value: = property(fget=__GetAzimuthEnd)
Defined in SpeosNX_2512.py at line 17189
AzimuthResolution : str
public static
Gets or sets the azimuth resolution.
Value type: Double (in degree).
Range: The value must be superior to 0.0.
The default value is 36 deg.
Default value: = property(fget=__GetAzimuthResolution, fset=__SetAzimuthResolution)
Defined in SpeosNX_2512.py at line 17197
AzimuthSampling : str
public static
Gets or sets the azimuth sampling.
Value type: Integer.
Range: The value must be superior or equal to 2.
The default value is 10.
Default value: = property(fget=__GetAzimuthSampling, fset=__SetAzimuthSampling)
Defined in SpeosNX_2512.py at line 17205
AzimuthStart : str
public static
Gets the azimuth start.
Value type: Double (in degree).
The default value is 0 deg.
Default value: = property(fget=__GetAzimuthStart)
Defined in SpeosNX_2512.py at line 17212
CustomAxisSystem : str
public static
Gets or sets the custom axis system property.
True: Enables custom axis system.
False: Disables custom axis system.
Value type: Boolean.
The default value is False.
Default value: = property(fget=__GetCustomAxisSystem, fset=__SetCustomAxisSystem)
Defined in SpeosNX_2512.py at line 17222
IncidentEnd : str
public static
Gets the incident angle end.
Value type: Double (in degree).
The default value is 90 deg.
Default value: = property(fget=__GetIncidentEnd)
Defined in SpeosNX_2512.py at line 17229
IncidentResolution : str
public static
Gets or sets the incident resolution.
Value type: Double (in degree).
Range: The value must be superior to 0.0.
The default value is 9 deg.
Default value: = property(fget=__GetIncidentResolution, fset=__SetIncidentResolution)
Defined in SpeosNX_2512.py at line 17237
IncidentSampling : str
public static
Gets or sets the incident sampling.
Value type: Integer.
Range: The value must be superior or equal to 2.
The default value is 10.
Default value: = property(fget=__GetIncidentSampling, fset=__SetIncidentSampling)
Defined in SpeosNX_2512.py at line 17245
IncidentStart : str
public static
Gets the incident angle start.
Value type: Double (in degree).
The default value is 0 deg.
Default value: = property(fget=__GetIncidentStart)
Defined in SpeosNX_2512.py at line 17252
Selections : str
public static
Returns the interface to select the oriented faces and bodies on which to measure the light distribution.
Value type: SensorLightFieldSelections object.
Default value: = property(fget=__GetSelections)
Defined in SpeosNX_2512.py at line 17258
Type : str
public static
Gets or sets the sensor type.
The values are:
0 - Photometric.
1 - Radiometric.
2 - Spectral.
Value type: Integer.
The default value is 1.
Default value: = property(fget=__GetType, fset=__SetType)
Defined in SpeosNX_2512.py at line 17270
WavelengthEnd : str
public static
Gets the wavelength end.
Value type: Double (in nm).
Range: The value must be superior to 0.0 and more than start value.
The default value is 700 nm.
Default value: = property(fget=__GetWavelengthEnd, fset=__SetWavelengthEnd)
Defined in SpeosNX_2512.py at line 17278
WavelengthResolution : str
public static
Gets or sets the wavelength resolution.
Value type: Double (in nm).
Range: The value must be superior to 0.0.
The default value is 25 nm.
Default value: = property(fget=__GetWavelengthResolution, fset=__SetWavelengthResolution)
Defined in SpeosNX_2512.py at line 17286
WavelengthSampling : str
public static
Gets or sets the wavelength sampling.
Value type: Integer.
Range: The value must be superior or equal to 2.
The default value is 13.
Default value: = property(fget=__GetWavelengthSampling, fset=__SetWavelengthSampling)
Defined in SpeosNX_2512.py at line 17294
WavelengthStart : str
public static
Gets the wavelength start.
Value type: Double (in nm).
Range: The value must be superior to 0.0 and less than end value.
The default value is 400 nm.
Default value: = property(fget=__GetWavelengthStart, fset=__SetWavelengthStart)
Defined in SpeosNX_2512.py at line 17302
Member Summary
| Member | Type |
|---|---|
ArrowLength |
public |
AxisSystem |
public |
AzimuthEnd |
public |
AzimuthResolution |
public |
AzimuthSampling |
public |
AzimuthStart |
public |
CustomAxisSystem |
public |
IncidentEnd |
public |
IncidentResolution |
public |
IncidentSampling |
public |
IncidentStart |
public |
Selections |
public |
Type |
public |
WavelengthEnd |
public |
WavelengthResolution |
public |
WavelengthSampling |
public |
WavelengthStart |
public |
thisown |
public |