System Coupling Commands
Last update: 21.07.2025This document provides detailed information on the commands you can use to interact with System Coupling from the command line, whether from System Coupling's command-line interface (CLI) or from the Command Console tab of its graphical user interface (GUI).
AddAerodampingDataTransfers
Description
Adds data transfer for each specified mode shape.
Returns the name of the Data Transfers created.
Essential Keyword Arguments
- Interface: String indicating the name of the interface on which the data transfer is to be created.
Optional Keyword Arguments
- ModeShapes: List of mode shapes to transfer. If not provided, a data transfer is created for each available modeshape.
Example
#Add a group of data transfers for aerodamping physics:
>>> AddAerodampingDataTransfers(Interface = "Interface-1", ModeShapes = ['ModeShape_Mode1_HI1', 'ModeShape_Mode3_HI2'])
['ModeShape_Mode1_HI1', 'ModeShape_Mode3_HI2']
AddDataTransfer
Description
Adds data transfer based on arguments that specify the interface, target side, and variables to be associated with each side of the interface. The command requires that you specify variables using their names, as described below in Essential Keyword Arguments. Either a variable-based or expression-based data transfer may be created with this command based on the Optional Keyword Arguments. If a variable-based data transfer argument is given, then no expression-based data transfer arguments can be used. If an expression-based data transfer argument is given, then no variable-based data transfer arguments can be used.
Cannot be run after participants have been started.
Returns the name of the Data Transfer created.
Essential Keyword Arguments
- Interface: String indicating the name of the interface on which the data transfer is to be created.
- TargetSide: String indicating the side of the interface to receive the data transfer variable. Possible values are 'One' or 'Two'.
Optional Keyword Arguments
- SourceVariable: String specifying the name of the variable on the source side of the data transfer. Used when creating a variable-based data transfer. Must be combined with TargetVariable.
- TargetVariable: String specifying the name of the variable on the target side of the data transfer. Must be combined with either SourceVariable (when creating a variable-based data transfer) or with Value{X|Y|Z} (when creating an expression-based data transfer).
- Value: String specifying the expression to use on the source side of the data transfer. Used when creating an expression-based data transfer. If the TargetVariable is a vector, a vector-valued expression must be provided. Alternatively, ValueX, ValueY, ValueZ may be used to specify the individual components of the vector expression.
- ValueX: String specifying the X component of the expression to use on the source side of the data transfer. This may optionally be used when creating an expression-based data transfer if the TargetVariable is a vector as an alternative to specifying a vector-valued expression in Value. ValueY and ValueZ are also required if ValueX is used.
- ValueY: String specifying the Y component of the expression to use on the source side of the data transfer. This may optionally be used when creating an expression-based data transfer if the TargetVariable is a vector as an alternative to specifying a vector-valued expression in Value. ValueX and ValueZ are also required if ValueY is used.
- ValueZ: String specifying the Z component of the expression to use on the source side of the data transfer. This may optionally be used when creating an expression-based data transfer if the TargetVariable is a vector as an alternative to specifying a vector-valued expression in Value. ValueX and ValueY are also required if ValueZ is used.
- SideOneVariable: String specifying the name of the variable associated with side1 of the interface. Must be combined with SideTwoVariable. Used only when creating variable-based data transfers. Consider using SourceVariable/TargetVariable parameters instead.
- SideTwoVariable: String specifying the name of the variable associated with side2 of the interface. Must be combined with SideTwoVariable. Used only when creating variable-based data transfers. Consider using SourceVariable/TargetVariable parameters instead.
Examples
Example 1
#Add a variable-based data transfer:
>>> AddDataTransfer(Interface = "Interface-1",
TargetSide = "One",
SourceVariable = "force",
TargetVariable = "FORC")
Example 2
#Add an expression-based data transfer:
>>> AddDataTransfer(Interface = "Interface-1",
TargetSide = "One",
TargetVariable = "Temperature",
Value = "300 [K] if Step < 3 else temperature")
Example 3
#Add an expression-based vector data transfer:
>>> AddDataTransfer(Interface = "Interface-1",
TargetSide = "One",
TargetVariable = "INCD",
Value = "vector(
INCD * Position.x / 1 [m],
INCD * Position.y / 0.5 [m],
INCD * Position.z / 0.02 [m])")
AddExpressionFunction
Description
Creates an expression function object in the data model that makes available an external Python function for use in expressions.
The parameters specified should correspond to a module and function that exists and can successfully be loaded when the application starts. Otherwise, the data model object will be created but there will be validation errors and the function will not be available for use.
Essential Keyword Arguments
- Module: The name of the Python module (in the 'Modules' sub-directory of the working directory) from which the function is to be obtained.
- Function: The name of the function in the module. If no FunctionName is specified, this will also be the name by which the function should be referenced when used in an expression.
Optional Keyword Arguments
- FunctionName: Optionally specify a different name from Function which should be the name used to reference the function in an expression.
Examples
Example 1
#If the parameters are valid, 'f' is available to be referenced with
#appropriate arguments in an expression - e.g. "2 * f(Time)".
>>>AddExpressionFunction(Module='my_module', Function='f')
Example 2
#If the parameters are valid, 'f1' is available to be referenced with
#appropriate arguments in an expression - e.g. "2 * f1(Time)".
>>>AddExpressionFunction(Module='my_module', Function='f', FunctionName='f1')
AddFSIDataTransfers
Description
Adds group of data transfers for FSI physics.
Returns the list of the data transfers created.
Essential Keyword Arguments
- Interface: String indicating the name of the interface on which the data transfer is to be created.
Optional Keyword Arguments
- UseForceDensity: Boolean indicating whether to prefer force density variable over force. Default value is False.
Example
#Add a group of data transfers for FSI physics:
>>> AddFSIDataTransfers(Interface = "Interface-1")
['FORC', 'displacement']
AddFlowBoundaryDataTransfers
Description
Adds group of data transfers for flow boundary coupling.
Returns the list of the data transfers created.
Essential Keyword Arguments
- Interface: String indicating the name of the interface on which the data transfer is to be created.
Example
#Add a group of data transfers for flow boundary coupling:
>>> AddFlowBoundaryDataTransfers(Interface = "Interface-1")
['mass-flow-rate', 'backflow-total-temperature']
AddInterface
Description
Adds an interface based on the participant and region names specified as arguments for each side of the interface. This command requires that you specify participants using their names as described below in Essential Keyword Arguments. Non-FMU participants can provide a list of regions as described below in Optional Keyword Arguments. For FMU interfaces, specifying the regions are not allowed.
Cannot be run after participants have been started.
Returns the name of the Interface created.
Essential Keyword Arguments
- SideOneParticipant: String indicating the name of the participant to be associated with side One of the interface.
- SideTwoParticipant: String indicating the name of the participant to be associated with side Two of the interface.
Optional Keyword Arguments
- SideOneRegions: List specifying the name(s) of region(s) to be added to side One of the interface. Must be provided if SideOneParticipant is not an FMU.
- SideTwoRegions: List specifying the name(s) of region(s) to be added to side Two of the interface. Must be provided if SideOneParticipant is not an FMU.
Examples
Example1
#Create interface by specifying participant name and region names for each
#side of the interface.
>>> AddInterface(SideOneParticipant = "MAPDL-1",
SideOneRegions = ["FSIN_1"],
SideTwoParticipant = "FLUENT-2",
SideTwoRegions = ["wall"])
Example2
#Create an interface between an FMU and a non-FMU participant.
>>> AddInterface(SideOneParticipant = "MAPDL-1",
SideOneRegions = ["FSIN_1"],
SideTwoParticipant = "FMU-2")
AddNamedExpression
Description
Creates a named expression object in the data model. If there is already an object in the data model whose 'ExpressionName' matches the provided ExpressionName, its 'ExpressionString' will be overwritten with the provided ExpressionString
Essential Keyword Arguments
- ExpressionName: The name by which this expression should be referenced when used in another expression.
- ExpressionString: String containing the definition of the expression.
Example
#create a named expression called 'twoPi' that evaluates to 2 * pi:
>>>AddNamedExpression(ExpressionName='twoPi', ExpressionString='2 * pi')
#'twoPi' is now available to be referenced in any other expression.
AddOrderedDataTransfers
Description
Adds data transfer for each ordered pair of variables in an FMU-FMU interface. Requires the FMU-FMU interface. Requires that the target FMU has the same number of input variables as the source FMU has output variables. The transfers are added in order. That is, the n-th output variable for side one will be connected to the n-th input variable for side two. This is only available for interfaces with FMUs on both side one and side two.
Data transfers will be created in both directions, if possible.
Returns the name of the data transfers created.
Essential Keyword Arguments
- Interface: String indicating the name of the interface on which the data transfer is to be created.
Example
#Add a group of ordered data transfers for an FMU-FMU interface:
>>> AddOrderedDataTransfers(Interface = "Interface-1")
['Real_1', 'Real_2', 'Real_3']
AddParticipant
Description
Adds a coupling participant to the setup. Cannot be called after participants have been started. Returns the name of the participant.
There are several options that can be selected to add the participant - via a file, via a participant executable, or via a Python script. Some of these options may be combined. For example, sometimes it is useful to use an input file while at the same time providing a custom participant executable or Python script.
Option 1: Using an input file
Given an input file containing participant coupling information, reads the specified file, pushes the participant's information to the data model.
Option 2: Using a participant executable
Given the path to the executable for this participant (and optionally, additional arguments and/or working directory), start the participant executable, connect to the participant using the socket connection, and get the participant's information and add it to the data model.
Option 3: Using a Python script
This can be seen as a special case of Option 2 (using an executable), but instead of an executable, a Python script is used. System Coupling will invoke a specialized script to set up the environment so that the Python script can more easily interact with System Coupling.
Optional Keyword Arguments
- ParticipantType: Participant type. To get a list of supported participant types, use the GetSupportedParticipantTypes() query. If unspecified, AddParticipant will attempt to deduce the type from InputFile.
- InputFile: Name of the input file for the participant to be added. Currently supported formats are SCP files, Forte input (FTSIM) files, mechanical server (.rst) files, cfd server (.csv) files, FMU (.fmu) files (Beta), and system coupling data server (*.scdt/axdt/csv) files.
- Executable: Path to the executable file for the participant to be added.
- AdditionalArguments: Any additional arguments to be passed to the participant's executable.
- WorkingDirectory: Path to the working directory for this participant.
- PythonScript: Instead of the executable, use a Python script and wrap it with System Coupling-provided .bat/.sh scripts to set up the environment correctly before calling this Python script. On Windows, a few lines will need to be included near the top of the Python script to add the required dll directories as follows: if sys.platform.startswith("win"): for p in os.environ["PYTHON_DLL_PATH"].split(os.pathsep): os.add_dll_directory(p)
Examples
Example1
#Add a participant to a coupled analysis via an input file:
>>> AddParticipant(InputFile = "MAPDL.scp")
Example2
#Add a participant to a coupled analysis via an executable:
>>> AddParticipant(Executable = "participantSolver.bat")
Example3
#Add a participant to a coupled analysis via a Python script:
>>> AddParticipant(PythonScript = "participantSolver.py")
Example4
#Add a participant to a coupled analysis via a Python script and
#an SCP file:
>>> AddParticipant(InputFile = "setup.scp",
PythonScript = "participantSolver.py")
AddReferenceFrame
Description
Add a reference frame to the datamodel
The function will add a blank reference frame to the datamodel. Any transformations must be added separately.
Reference frame name will be "Frame-#" where # is the first positive integer which yields a unique frame name.
Returns the name of the reference frame.
Optional Keyword Arguments
- ParentReferenceFrame: Name of a reference frame that the added frame should use as the parent. If the argument is not provided, the default parent reference frame "GlobalReferenceFrame" will be added.
Example
#Add a reference frame with a parent reference frame:
>>> AddReferenceFrame(ParentReferenceFrame = "Frame-3")
'Frame-4'
AddThermalDataTransfers
Description
Adds group of data transfers for thermal physics.
Returns the list of the data transfers created.
Essential Keyword Arguments
- Interface: String indicating the name of the interface on which the data transfer is to be created.
Optional Keyword Arguments
- Option: Thermal data transfer option: 'Heat Rate' (default) or 'Heat Transfer Coefficient' (possible for surface-surface transfers).
Example
#Add a group of data transfers for thermal physics:
>>> AddThermalDataTransfers(Interface = "Interface-1", Option = 'HeatRate')
['temperature', 'HFLW']
AddTransformation
Description
Add a transformation to a reference frame defined in the datamodel
Given the reference frame to add to the transform to, the type of transform to be added, and any required information for the transformation, add the transformation to the referenceFrame. Not all parameters are required for every transformation.
The name of the transformation will be based on the type of transformation. The name will be of the form "<TransformationType>-#" where # is the first positive integer which yields a unique frame name.
The transformation will also be added to the end of the TransformationOrder list for the reference frame.
Returns the name of the transformation.
Essential Keyword Arguments
- ReferenceFrame: Name of the reference frame to which the transformation will be added.
- TransformationType: Type of transformation to be added. Available options are Rotation or Translation
Required Parameters for Transformation Types: Rotation: Angle, Axis, Vector (if Axis is "UserDefined") Translation: Vector
Optional Keyword Arguments
- Angle: Angle to rotate a reference frame. Used with Rotation TransformationType. Default unit is Radians.
- Axis: Axis about which a rotation is applied. Used with Rotation TransformationType. Available options are: "XAxis", "YAxis", "ZAxis", and "UserDefined".
- Vector: A vector for use with Translation TransformationType or Rotation TransformationType if the Axis is "UserDefined".
Example
#Add a translation transformation to a reference frame:
>>> AddTransformation(
ReferenceFrame = "Frame-1",
TransformationType = "Rotation",
Axis = "XAxis",
Angle = "7 [deg]")
'Rotation-3'
ClearState
Description
Clears the state of the entire System Coupling service, removing all data model items, parameter values, and calculated values.
Cannot be run after participants have been started.
ConnectEnSightDVS
Description
Allow System Coupling to create DVS clients and connect these clients to the dvs server that is already launched in another process/thread remotely.
When this command is issued, System Coupling is connected to remote EnSight and the in-situ data streaming from system coupling to EnSight is ready.
Optional Keyword Arguments
- Port: DVS Server port that System Coupling would connect to. Default value is 50055.
- HostName: DVS Server host name that System Coupling would connect to. Default value is "127.0.0.1".
Example
#Connect to EnSight DVS server launched in the machine with the
#above host name and port number.
>>> ConnectEnSightDVS(Port=50055,HostName="127.0.0.1")
CreateNamedExpression
Description
Important: this command is deprecated and will be removed in a future release. The command AddNamedExpression has identical functionality and should be used instead.
Creates a named expression object in the data model. If there is already an object in the data model whose 'ExpressionName' matches the provided ExpressionName, its 'ExpressionString' will be overwritten with the provided ExpressionString.
Essential Keyword Arguments
- ExpressionName: The name by which this expression should be referenced when used in another expression.
- ExpressionString: String containing the definition of the expression.
Example
#create a named expression called 'twoPi' that evaluates to 2 * pi:
>>>CreateNamedExpression(ExpressionName='twoPi', ExpressionString='2 * pi')
#'twoPi' is now available to be referenced in any other expression.
CreateRestartPoint
Description
Interactive command that creates a restart point at the end of the last completed coupling step.
Signals the System Coupling service and all coupling participants that a restart point should be created before the next coupling step begins. The restart point is created in addition to restart points created by the 'OutputControl' setting in the data model.
Note that some participants write their restart files only when the coupling run resumes, so their files will not be available immediately after the command is issued.
Results information for the coupling step is written to a file named according to the convention "Results_step<#>|iter<#>.h5", where "#" is the number of the coupling step or iteration. The restart files are written to the "SyC" directory, which is automatically created by System Coupling.
DeleteObject
Description
Deletes the specified object from the data model.
Essential Keyword Arguments
- ObjectPath: String indicating the path of the object to be deleted.
Example
#Delete an interface object from the data model
>>> DeleteObject(ObjectPath = '/SystemCoupling/CouplingInterface:
interface-1')
DeleteSnapshot
Description
Deletes the specified snapshot. If the snapshot does not exist, an error will be raised.
Essential Keyword Arguments
- SnapshotName: Name of the snapshot to be deleted.
Example
#Delete a snapshot called 'Initial'
>>> DeleteSnapshot(SnapshotName='Initial')
DeleteTransformation
Description
Delete a transformation from a reference frame
In addition to deleting the transformation object, it will also remove the transformation from TransformationOrder (if it exists in that list).
Essential Keyword Arguments
- ReferenceFrame: Name of the reference frame from which the transformation will be deleted.
- TransformationName: Name of the transformation which will be deleted.
Example
#Delete a transformation from a reference frame:
>>> DeleteTransformation(
ReferenceFrame = "Frame-1",
TransformationName = "Rotation-3")
ExecuteCommandString
Description
Executes a command in the Python interpreter, enabling you to issue a generic Python command to the System Coupling Service.
Essential Keyword Arguments
- CommandString: String indicating the command to be executed.
Example
#Execute a command string to print the state of a singleton
>>> ExecuteCommandString(CommandString = 'DatamodelRoot()
.OutputControl.PrintState()')
OutputControl
Option = LastStep
GenerateInputFile
Description
Generates the input journal file for a given Fluent participant.
Available for Fluent participants when FluentInput.Option is not set to JournalFile.
Given the participant's name and a file name, generates a Fluent journal script which may be set as the value for the JournalFile setting.
System Coupling uses the generated scrkpt for the coupled analysis.
Scripts generated using this method may be edited before the coupled analysis is started.
Essential Keyword Arguments
- ParticipantName: Name of the participant for which the execution command will be returned.
- FileName: Name of the journal script to be written. Note that this name is relative to the participant's working directory.
Example
#Get a participant's execution command
>>> GenerateInputFile(ParticipantName = 'FLUENT-1', FileName = 'fluent.jou')
GetErrors
Description
If errors exist, returns them as a list of dictionaries containing error details; otherwise, returns an empty list. See also: GetErrorsXML().
GetExecutionCommand
Description
Gets the execution command needed to start the specified participant.
Essential Keyword Arguments
- ParticipantName: Name of the participant for which the execution command will be returned.
Example
#Get a participant's execution command
>>> GetExecutionCommand(ParticipantName = 'MAPDL-1')
'"C:\Program Files\ANSYS Inc\v261\ansys\bin\winx64\ANSYS252.exe"
-b nolist -s noread -o MAPDL-1.out -scport 55122
-schost 127.0.0.1 -scname "MAPDL-1" -i ds.dat'
GetRegionNamesForParticipant
Description
This query is deprecated and will be deleted in future releases. To get region names for a participant, you can use GetChildNames() query, for example:
DatamodelRoot().CouplingParticipant[name].Region.GetChildNames()
Essential Keyword Arguments
- ParticipantName: Name of the participant.
GetTransformation
Description
Given an interface and side, returns the resultant transformation, in the form of a Python dictionary and formatted as a DataModel ReferenceFrame object. If multiple transformations are applied to the interface side, the composite transformation is returned.
This command can only be invoked after the analysis is initialized.
Essential Keyword Arguments
- InterfaceName: Name of the interface
- Side: Interface side. Can be "One" or "Two".
Example
#Get the transformation for an interface side:
>>> t = GetTransformation(InterfaceName = "Interface-1", Side = "One")
ImportSystemCouplingInputFile
Description
Reads the specified System Coupling SCI file and pushes its information into the data model. The SCI file is the required System Coupling input format for the initial run of a coupled analysis set up in Workbench.
After the initial run based on an imported SCI file, a reissue of the ImportSystemCouplingInputFile command is unnecessary and is not recommended unless the setup has changed.
Cannot be run after participants have been started.
Essential Keyword Arguments
- FilePath: Path and file name for the SCI file to be read.
Example
#Import an SCI file for an initial run
>>> ImportSystemCouplingInputFile(FilePath = 'scInput.sci')
Initialize
Description
Interactive command that initializes a coupled analysis.
Initialization includes preparing System Coupling, making connections between System Coupling and all participants, starting participants (if necessary), and writing participant build information to the Transcript and Log.
Note that if the ExecutionControl Option for a participant is set to ExternallyManaged, then System Coupling will not start the participant using either this command or any of the other commands that automatically start participants. The user is expected to manually start the participant. This function will not return until all participants have been connected.
Note that this command will raise an exception if another instance of System Coupling is solving in the current working directory.
Map
Description
Command to perform map operation.
When user friendly mapping workflow is enabled, this command will perform the map operation between the interfaces as part of the user friendly mapping workflow. Otherwise, this operation would clears all existing state, except for datamodel, before beginning the operation.
Open
Description
Reads the state of a coupled analysis. The state consists of settings to populate the datamodel and results to restart the analysis at the end of a specified coupling step.
Settings are stored in a file named Settings.h5. Results files may correspond either to coupling iterations or coupling steps, depending on the analysis type and the types of participants involved.
By default, this command looks for the "SyC" directory in the current working directory. By default, if multiple Results files exist, the most recent one is opened.
If given optional arguments, behaves as described below in "Optional Keyword Arguments".
Cannot be run after the participants have been started.
Optional Keyword Arguments
- FilePath: Directory containing the .h5 file(s) to be read. When used, the System Coupling Service looks for files in the specified directory. Default is 'SyC'. It is recommend to not use anything other than a default directory for the FilePath.
- CouplingStep: Integer specifying the coupling step at which the coupled analysis is restarted. When used, System Coupling reads the corresponding Results_step<#>.h5 file in the specified directory and restarts the analysis at the end of the specified coupling step. When this argument is used, System Coupling automatically removes the output files related to all later coupling steps. If the files cannot be removed, then System Coupling generates an exception message instructing you to free up the files and reissue the Open command with the CouplingStep argument. If the simulation's Results files are associated with coupling iterations, then System Coupling prints an error message indicating this.
- CouplingIteration: Integer specifying the coupling iteration at which the coupled analysis is restarted. When used, System Coupling reads the corresponding Results_iter<#>.h5 file in the specified directory and restarts the analysis at the end of the specified coupling iteration. When this argument is used, System Coupling automatically removes the output files related to all later coupling iterations. If the files cannot be removed, then System Coupling generates an exception message instructing you to free up the files and reissue the Open command with the CouplingIteration argument. If the simulation's Results files are associated with coupling steps, then System Coupling prints an error message indicating this.
Examples
Example 1
#Load the last solved coupling step
>>> Open()
Example 2
#Load coupling step 6
>>> Open(CouplingStep = 6)
Example 3
#Load coupling iteration 7
>>> Open(CouplingIteration = 7)
OpenResultsInEnSight
Description
Allows for System Coupling results to be postprocessed in EnSight.
When this command is issued, System Coupling looks for the Results.enc file in the SyC/Results subdirectory of the current working directory.
When System Coupling finds the file, it loads the file into EnSight and generates a confirmation message indicating that results are being opened.
If System Coupling is unable to find the Results.enc file and/or the EnSight executable, then it raises an error.
The OpenResultsInEnSight command may be issued multiple times from the same instance of System Coupling. Each time the command is issued, a new instance of the EnSight application is opened. Any existing instances of EnSight remain open, both when additional instances are created and when System Coupling exits.
Optional Keyword Arguments
- FileName: The basename of the EnSight case file if using a non-standard file name. Overrides the default file name "Results".
- FilePath: The path to the EnSight case if using a non-standard location. Overrides the default path of SyC/Results.
Example
#Open results in EnSight using the default file name and path:
>>> OpenResultsInEnSight()
"Results are being opened in EnSight"
OpenSnapshot
Description
Opens a snapshot containing a previously saved state of the simulation. All state (files and directories) stored in the snapshot will be restored. If other state exists in the working directory, then it will not be modified by this command.
Note: Snapshot cannot be opened if participants have been started.
Optional Keyword Arguments
- SnapshotName: The name of the snapshot to be opened. This is optional if and only if there is only one snapshot available to be loaded. If multiple snapshots exist, then the snapshot name must be specified.
Example
#Open a snapshot called 'InitialState'
>>> OpenSnapshot(SnapshotName='InitialState')
PartitionParticipants
Description
Provide a utility for setting the parallel algorithm, parallel partitioning fractions for each participant, and machine list information.
At least one participant must be defined for this command to be used. Use of this command is not recommended if participants are already running.
Note: Ansys recommends only using this command for the Custom partitioning algorithm.
When other algorithms are used (SharedAllocateMachines, DistributedAllocateCores, etc.) the algorithm should be specified directly, for example:
DatamodelRoot().AnalysisControl.PartitioningAlgorithm = "SharedAllocateMachines"
The participant parallel fractions can also be specified directly, for example:
DatamodelRoot().CouplingParticipant["FLUENT-1"].ExecutionControl.ParallelFraction = 0.5
The machine list should be specified via System Coupling command line arguments, for example:
Optional Keyword Arguments
- AlgorithmName: Name of the partitioning algorithm. Available algorithms are: 'SharedAllocateMachines'(default), 'SharedAllocateCores', 'DistributedAllocateMachines', 'DistributedAllocateCores', and 'Custom' (please see PartitioningInfo section below for more details for this algorithm). The algorithms allow for both shared and distributed execution and for the allocation of machines or cores. The default value is generally the best choice, as it allows for each participant to take advantage of all the allocated resources. The other partitioning methods are provided to handle situations where not enough resources are available to run the same machines. See the System Coupling documentation for more details of the partitioning algorithms.
- NamesAndFractions: List of tuples specifying the fractions of core count applied for each participant. Each tuple must have the ParticipantName as its first item and the associated fraction as its second item. If this parameter is omitted, then cores will be allocated for all participants set in the data model.
- MachineList: List of dictionaries specifying machines available for distributed run. Each dictionary must have a key 'machine-name' with machine name as its value, and key 'core-count' with number of cores for that machine as its value. Providing this argument will over-ride any machine-list information detected from the scheduler environment and any information provided by the --cnf command-line argument.
- PartitioningInfo: Dictionary specifying machines resources assigned to each participant by user. Dictionary must have participant names as keys and machineLists containing machine resources as values. The value of PartitioningInfo machineList is a list of dictionaries specifying machines assigned to corresponding participants. Each dictionary of machineList must have a key 'machine-name' with machine name as its value, and key 'core-count' with number of cores for that machine as its value. Providing this argument will disallow other arguments except AlgorithmName, which must set as 'Custom' if provided. Otherwise, AlgorithmName will be set as 'Custom' internally if PartitioningInfo is provided.
Example
#Allocate machine resources for participants based on custom partitioning information.
#In this example, FLUENT-1 participant will run on machine "host-1" and "host-2"
#with 19 cores, and MAPDL-2 participant will run on machine "host-3" with 8 cores.
>>> PartitionParticipants(
PartitioningInfo={"FLUENT-1":[{"machine-name":"host-1","core-count":10},
{"machine-name":"host-2","core-count":9}],
"MAPDL-2":[{"machine-name":"host-3","core-count":8}]})
PrintExpressionVariables
Description
Given a path to an object, and a parameter name, print a list of variables which can be used in an expression assigned to the parameter. For convenience, as a special case, the parameter name may be omitted if the path is to a DataTransfer object.
If an expression cannot be used at the specified data model location, or if there are no valid variables which can be used in the expression, then no output will be printed.
For the purposes of the command, "valid" means that the variable may be used in the expression. Note however that "valid" does not necessarily mean that a variable can be used in the expression. Other validation rules may preclude the use of the variable. See the user documentation for more details.
For the DataTransfer case, the list of variables will be ordered with the most likely variables first. That is, those sharing the same quantity type and/or dimensionality as the target of the expression.
Essential Keyword Arguments
- ObjectPath: String indicating the path of the object to print expression variables for.
Optional Keyword Arguments
- ParameterName: String indicating the name of the parameter to print expression variables for. Note: this is optional only if ObjectPath is a path to a DataTransfer object.
Example
#Get source side variables for a data transfer
>>> PrintExpressionVariables(ObjectPath = '/SystemCoupling/CouplingInterface:Interface-1/DataTransfer:Transfer-1')
+-----------------------------------------------------------------------------+
| Available Variables |
+-----------------------------------------------------------------------------+
| Variable | Tensor Type Dimension |
+-----------------------------------------------------------------------------+
| Target | |
| Loss | (Scalar) [kg m^2 s^-3] |
| Source | |
| heatflow | (Scalar) [kg m^2 s^-3] |
| Position | (Vector) [m] |
| Normal | (Vector) [ ] |
| Area | (Scalar) [m^2] |
| Step | (Scalar) [ ] |
| Iteration | (Scalar) [ ] |
| Time | (Scalar) [s] |
+-----------------------------------------------------------------------------+
PrintSetup
Description
Prints a summary of the System Coupling setup.
PrintSnapshots
Description
Prints a list of available snapshots.
Example
#Print all available snapshots:
>>> PrintSnapshots()
+-------------------------------------------------------------------+
| Available Snapshots |
+-------------------------------------------------------------------+
| FinalState |
| Steps : 1, 3, 5 |
| Initial |
| Steps : |
+-------------------------------------------------------------------+
ReadScriptFile
Description
Reads a script file in the command environment.
Essential Keyword Arguments
- FileName: Name of the script file that is to be read.
Example
#Read a Python script file
>>> ReadScriptFile(FileName = 'run.py')
ReloadExpressionFunctionModules
Description
This may be called to force a reload of expression function modules if they have changed since they were last loaded.
Save
Description
Saves the state of the coupled analysis data model.
Analysis settings are written to a single Settings.h5 file which can be used to reload analysis settings.
Restart files for all restart points in the current co-simulation will be written when this command is called. Existing restart files from previous System Coupling versions will be renamed to conform to the new naming scheme.
Restart files are named according to the convention Restart_step#.h5 or Restart_iter#.h5, where "#" is the index of the corresponding coupling step or iteration.
Returns a Boolean value of 'True' if the files were saved successfully; otherwise, returns a value of 'False'.
Note that this command will raise an exception if another instance of System Coupling is solving in the current working directory.
If given optional arguments, then behaves as described below in "Optional Keyword Arguments."
Optional Keyword Arguments
- FilePath: Writeable directory to which the SyC directory is added. (Settings and Results .h5 files will be written to the SyC directory.). Ansys does not recommend changing the default value of this argument.
Example
#Save the state of a coupled analysis in a "SyC" directory under current
#working directory.
>>> Save()
True
SaveSnapshot
Description
Saves a snapshot of the current state of the simulation. Snapshot will contain all files and directories within the working directory that are tracked by System Coupling: the SyC directory and the working directories of all loaded participants. Before saving the snapshot, the current datamodel will be saved.
Note: Snapshot cannot be saved if participants have been started.
Note: If files required for cosimulation are not stored within the working directory, then they will not be included in the snapshot.
Essential Keyword Arguments
- SnapshotName: Name of the snapshot to be saved.
Optional Keyword Arguments
- OverwriteExisting: Boolean argument controlling whether an existing snapshot should be overwritten. If True, then an existing snapshot named SnapshotName will be overwritten if it exists. If False (default), then if SnapshotName is shared with an existing snapshot, a warning will be written and the command will return without saving the snapshot.
Example
#Save a snapshot called 'InitialState'
>>> SaveSnapshot(SnapshotName='InitialState')
SetState
Description
Sets the state of a specified datamodel container (can be either a singleton or an object).
Returns a Boolean value of 'True' if the state was updated; otherwise, returns a value of 'False'. (The latter would happen if a value were set that is no different from the value already in the state.)
By default, System Coupling will allow settings to be made that are not currently available in the datamodel, as long as they are settings that are potentially available. They will not show up in the datamodel if they are not currently available, but if the state is later adjusted such that the settings become available, the values that were previously set will be seen.
This behavior can be controlled by the optional 'VerifyCommittedState' argument. This will cause a check to be performed for submission of unavailable settings, and an exception will be raised if the check fails. Note that, despite the exception, the settings will remain committed.
Essential Keyword Arguments
- ObjectPath: String indicating the path of the container to have its state set.
- State: Dictionary with the container state (settings) as keys and setting values as values.
Optional Keyword Arguments
- VerifyCommittedState: Boolean to control whether to check whether only settings that are currently available have been submitted. If the check is performed and it fails, an exception will be raised.
Examples
Example 1
#Use 'SetState' on a singleton
>>> SetState(ObjectPath = '/SystemCoupling/AnalysisControl/GlobalStabilization',
State = {'Option': 'Quasi-Newton'})
True
Example 2
#Using 'SetState' on an object
>>> SetState(ObjectPath = '/SystemCoupling/CouplingParticipant:MAPDL-1
/Variable:FORC', State = {'QuantityType': 'Force', 'DisplayName':
'TestForce'} )
True
Shutdown
Description
Interactive command that shuts down a coupled analysis.
Shutdown includes ending the coupling run and signaling participants to end the run. This produces a clean shutdown, generating the final restart point and corresponding Results file before disconnecting from participants.
After participants are disconnected, the coupling service writes timing details to the transcript. If participants were started automatically, it ends participant processes.
When System Coupling disconnects from the analysis and shuts down, the GUI Server file is removed from the working directory.
Solve
Description
Solves the coupled analysis. This command will execute until end coupled analysis is reached, or it is interrupted or aborted (for example, via scStop file).
Disabled when a solution is already in progress.
For restarts, the Open command must be run before the Solve command.
Note that if the ExecutionControl Option for a participant is set to ExternallyManaged, then System Coupling will not start the participant using either this command or any of the other commands that automatically start participants. The user is expected to manually start the participant. This function will not return until all participants have been connected.
Note that this command will raise an exception if another instance of System Coupling is solving in the current working directory.
Step
Description
Interactive command that initializes the analysis (if necessary) and runs the specified number of coupling steps before pausing the coupled analysis.
Disabled when a solution is already in progress.
Disabled for iterations-only steady analyses.
By default, runs a single step. If given the optional 'Count' argument, then runs the specified number of steps.
For restarts, the 'Open' command must be run before the 'Step' command.
When you run this command, System Coupling initializes the analysis if needed and then begins the solution. When the specified number of coupling steps has been run, the solution is paused, providing you with an opportunity to interact with the analysis.
Note that if the ExecutionControl Option for a participant is set to ExternallyManaged, then System Coupling will not start the participant using either this command or any of the other commands that automatically start participants. The user is expected to manually start the participant. This function will not return until all participants have been connected.
When the solution is resumed, either by reissuing this command or by running the Solve command, System Coupling restarts the analysis at the point it left off and continues the solution with the next step.
Note that this command will raise an exception if another instance of System Coupling is solving in the current working directory.
Optional Keyword Arguments
- Count: Integer specifying the number of steps to be run. Defaults to 1.
Examples
Example 1
#Use the default (the analysis runs one coupling step)
>>> Step()
Example 2
#Specify that the analysis runs three coupling steps
>>> Step(Count = 3)
UpdateInterfaces
Description
Command to apply transformation and instance defined in the interfaces. And display mapping mesh with the transformation and instance applied in the System Coupling viewer.
The purpose of this command is to visually confirm the correctness of coupling interfaces definition, alignment and instancing settings, and to allow modifying those settings to fix any issues ("nudge" the alignment, etc.)
UpdateParticipant
Description
Given the name of a participant, updates the state of the participant.
Available for DEFAULT-SRV, CFD-SRV, MECH-SRV, and SCDT-SRV and AEDT participants.
As part of the update, System Coupling updates all regions, variables, and parameters defined in the participant, including all variable attributes. Regions, variables, and parameters may be added to the participant but may not be removed.
You may specify an input file using an optional argument. If an input file is not provided, then the original input file will be reimported.
Note: AEDT participants must be updated using an scp file.
If the update process fails, System Coupling displays an error. In this case, you can either update the setup in the participant application to remove any issues with the update process or delete the participant from the analysis and then re-add it using the updated input file.
Essential Keyword Arguments
- ParticipantName: Participant name. Must be the name of an existing participant.
Optional Keyword Arguments
- InputFile: Name of the input file for the participant to be added. Currently supported formats are SCP files, mechanical server (.rst) files, cfd server (.csv) files, and system coupling data server (*.scdt/axdt/csv) files.
Examples
Example1
#Update a participant:
>>> UpdateParticipant(ParticipantName = "MECH-SRV-1")
Example2
#Update a participant using a new input file:
>>> UpdateParticipant(ParticipantName = "MECH-SRV-1", InputFile = "new.rst")
WriteCsvChartFiles
Description
For each coupling interface, exports a CSV file containing chart data (convergence and source/target quantity transfer values) for that interface.
Each file is named according to the convention
This command will overwrite any CSV charting files that already exist, including any that were written during the solution.
WriteEnSight
Description
Write a file with mesh and results which can be loaded into EnSight for post processing.
Essential Keyword Arguments
- FileName: Base name for EnSight files. It will generate
.encas file which should be loaded into EnSight. Other files are generated for geometry and variables.
Optional Keyword Arguments
- Binary: To control if file is to be written in binary format or ASCII. ASCII slows down performance, but may be useful for debugging and seeing raw data.
Examples
Example 1
#Write EnSight file with base name of 'test'
>>> WriteEnSight(FileName='test')
Example 2
#Write EnSight file with base name of 'test' in ASCII
>>> WriteEnSight(FileName='test', Binary = False)
WriteTargetData
Description
Command to write target data for target participant after mapping operation.
The purpose of this command is to write target mesh and target mapped data in the target participant working directory and thus mapping results from SystemCoupling can be check in the target participant.
Optional Keyword Arguments