The flow of Pulse-Width Modulation is 1 during the first part of the period and 0 during the second one for every number of cycles. The length of the part is defined by the duty cycle, from 0% to 100% of the period.

The figure shows the output flow for a PWM with the following inputs:

  • cycles: 10
  • dutyCycle: 0.7 (70%)
  • amplitude: 1
  • offset: 0

Interface

Name Kind Type Comment
cycles I unsigned Number of cycles for a period
Range: > 1
dutyCycle I float Switch reference value for on power, expressed in percent, 100% being fully on.
Range: [0, 1]
amplitude I float Gain to be applied to the output flow (default 1)
offset I float Offset to be added to the output flow (default 0)
flow O float Output flow

Parent topic:Sources::N