result:euler load buckling
Last update: 31.07.2026Version: 0.0.0
Description
Computing Euler's Critical Load. Formula: Ncr = nEIpipi /(L*L)
Inputs
This table lists the input pins for this operator. Input pins define the data that the operator requires to perform its operation. Some inputs are required, while others are optional and provide additional configuration. Each parameter is detailed in the sections that follow the table.
| Pin number | Name | Status | Expected type(s) |
|---|---|---|---|
| 5 | field_beam_end_condition | Required | data_sources, field |
| 6 | field_beam_moment_inertia | Required | field |
| 7 | field_beam_young_modulus | Required | field |
| 8 | field_beam_length | Required | field |
field_beam_end_condition (Pin 5)
- Required: Yes
- Expected type(s):
data_sources,field
This pin contains file csv or field of beam's end condition added by the user. If there's no file added, it would take value of all beam's end condition as 1.
field_beam_moment_inertia (Pin 6)
- Required: Yes
- Expected type(s):
field
Field of beam's moment inertia
field_beam_young_modulus (Pin 7)
- Required: Yes
- Expected type(s):
field
Field of beam's young modulus
field_beam_length (Pin 8)
- Required: Yes
- Expected type(s):
field
Field of beam's length
Outputs
This table lists the output pins for this operator. Output pins provide the results of the operator's computation and can be connected to inputs of other operators or retrieved for further processing. Each output is detailed in the sections that follow the table.
| Pin number | Name | Expected type(s) |
|---|---|---|
| 0 | field_euler_critical_load | field |
| 1 | field_euler_critical_load_yy | field |
| 2 | field_euler_critical_load_zz | field |
field_euler_critical_load (Pin 0)
- Expected type(s):
field
This field contains Euler's Critical Load about the principle axis of the cross section having the least moment of inertia.
field_euler_critical_load_yy (Pin 1)
- Expected type(s):
field
This field contains Euler's Critical Load on axis y.
field_euler_critical_load_zz (Pin 2)
- Expected type(s):
field
This field contains Euler's Critical Load on axis z.
Configurations
This operator supports configuration options that modify its behavior.
mutex
- Expected type(s):
bool - Default value: false
If this option is set to true, the shared memory is prevented from being simultaneously accessed by multiple threads.
Scripting
This operator can be accessed through scripting interfaces using these identifiers.
Category: result
Plugin: core
Scripting name: euler_load_buckling
Full name: result.euler_load_buckling
Internal name: euler_load_buckling
License: any_dpf_supported_increments
Examples
These examples demonstrate how to use this operator in different programming environments. Each example shows how to instantiate the operator, connect the required inputs, and retrieve the output.
C++
#include "dpf_api.h"
ansys::dpf::Operator op("euler_load_buckling"); // operator instantiation
op.connect(5, my_field_beam_end_condition);
op.connect(6, my_field_beam_moment_inertia);
op.connect(7, my_field_beam_young_modulus);
op.connect(8, my_field_beam_length);
ansys::dpf::Field my_field_euler_critical_load = op.getOutput<ansys::dpf::Field>(0);
ansys::dpf::Field my_field_euler_critical_load_yy = op.getOutput<ansys::dpf::Field>(1);
ansys::dpf::Field my_field_euler_critical_load_zz = op.getOutput<ansys::dpf::Field>(2);
CPython
import ansys.dpf.core as dpf
op = dpf.operators.result.euler_load_buckling() # operator instantiation
op.inputs.field_beam_end_condition.connect(my_field_beam_end_condition)
op.inputs.field_beam_moment_inertia.connect(my_field_beam_moment_inertia)
op.inputs.field_beam_young_modulus.connect(my_field_beam_young_modulus)
op.inputs.field_beam_length.connect(my_field_beam_length)
my_field_euler_critical_load = op.outputs.field_euler_critical_load()
my_field_euler_critical_load_yy = op.outputs.field_euler_critical_load_yy()
my_field_euler_critical_load_zz = op.outputs.field_euler_critical_load_zz()
IPython
import mech_dpf
import Ans.DataProcessing as dpf
op = dpf.operators.result.euler_load_buckling() # operator instantiation
op.inputs.field_beam_end_condition.Connect(my_field_beam_end_condition)
op.inputs.field_beam_moment_inertia.Connect(my_field_beam_moment_inertia)
op.inputs.field_beam_young_modulus.Connect(my_field_beam_young_modulus)
op.inputs.field_beam_length.Connect(my_field_beam_length)
my_field_euler_critical_load = op.outputs.field_euler_critical_load.GetData()
my_field_euler_critical_load_yy = op.outputs.field_euler_critical_load_yy.GetData()
my_field_euler_critical_load_zz = op.outputs.field_euler_critical_load_zz.GetData()
Changelog
- Version 0.0.0: Initial release.