Skip to main content

DPF Framework 2026 R1

sound:compute sharpness DIN 45692

Last update: 31.07.2026

Version: 0.0.0

Description

Compute the overall sharpness and sharpness over time of a signal, where sharpness is defined in accordance with the DIN 45692 standard. The overall sharpness calculation uses the specific loudness computed according to the ISO 532-1 standard for stationary sounds as a basis. The sharpness over time calculation uses the specific loudness computed according to the ISO 532-1 standard for time-varying sounds as a basis.

Inputs

Input Name Expected type(s) Description
Pin 0
Required
input_signal field Input in Pa on which to compute the DIN 45692 sharpness.
Pin 1 field_type string Field type associated with the recording conditions.

Supported values:

* Free
* Diffuse

Default: Free

Outputs

Output Name Expected type(s) Description
Pin 0 sharpness double Overall sharpness in acum (based on ISO 532-1 stationary specific loudness).
Pin 1 max_sharpness double Maximum sharpness over time in acum (based on ISO 532-1 time-varying specific loudness).
Pin 2 sharpness_over_time field Sharpness over time in acum (based on ISO 532-1 time-varying specific loudness).

Configurations

Name Expected type(s) Default value Description
mutex bool false If this option is set to true, the shared memory is prevented from being simultaneously accessed by multiple threads.

Scripting

Category: sound

Plugin: sound

Scripting name: None

Full name: None

Internal name: compute_sharpness_din45692

License: avrxp_snd_level1

Changelog

  • Version 0.0.0: Initial release.