Skip to main content

DPF Framework 2026 R1

sound:compute tonality aures

Last update: 31.07.2026

Version: 0.0.0

Description

Compute the tonality of a signal, according to the Aures model (W. Aures, 'Procedure for calculating the sensory pleasantness of various sounds', Acustica 59 (2), December 1985, pp. 130-141).

Inputs

Input Name Expected type(s) Description
Pin 0
Required
input_signal field Input signal in Pa on which to compute the Aures tonality.
Pin 1 overlap double Percentage in % of each window that overlaps with the next. Default: 90 %.
Pin 2 account_w1 bool Enable (True) or disable (False) the bandwidth weighting w1. Default: False.
Pin 3 bw_weighting_threshold double Threshold in dB for the bandwidth weighting w1. The threshold value is ignored if input account_w1 is set to False. Default value: 3 dB.

Outputs

Output Name Expected type(s) Description
Pin 0 tonality double Overall tonality in tonality units (tu).
Pin 1 tonality_over_time_tu field Tonality over time in tu.
Pin 2 wt_over_time field Tonal component weighting wT over time.The tonal component weighting combines 3 weighting functions related to the bandwidth, the frequency, and the prominence of each detected tone.
Pin 3 wGcr_over_time field Relative loudness weighting wGr over time.The relative loudness weighting accounts for the relative contribution of the tonal loudness to the overall loudness.

Configurations

Name Expected type(s) Default value Description
mutex bool false If this option is set to true, the shared memory is prevented from being simultaneously accessed by multiple threads.

Scripting

Category: sound

Plugin: sound

Scripting name: None

Full name: None

Internal name: compute_tonality_aures

License: avrxp_snd_level1

Changelog

  • Version 0.0.0: Initial release.