Skip to main content

DPF Framework 2026 R1

result:members in compression not certified

Last update: 31.07.2026

Version: 0.0.0

Description

This operator is a non-certified example of buckling resistance verification for the compression members for Class I, 2 and 3 cross-sections. It is only provided as an example if you want to develop your own compute norm operator. The results computed by this beta operator have not been certified by ANSYS. ANSYS declines all responsibility for the use of this operator.

Inputs

This table lists the input pins for this operator. Input pins define the data that the operator requires to perform its operation. Some inputs are required, while others are optional and provide additional configuration. Each parameter is detailed in the sections that follow the table.

Pin number Name Status Expected type(s)
0 time_scoping scoping, vector<int32>, int32
1 field_yield_strength Required data_sources, field
2 field_end_condition Required data_sources, field
3 streams streams_container
4 data_sources data_sources
5 manufacture Required bool
6 partial_factor Required double
7 mesh Required abstract_meshed_region
8 axial_force Required fields_container
12 fabrication_type Required bool

time_scoping (Pin 0)

time/freq set ids (use ints or scoping)

field_yield_strength (Pin 1)

This pin contains file csv or field of beam's Yield Strength.

field_end_condition (Pin 2)

This pin contains file csv or field of beam's end condition defined by the user. If no input at this pin found, it would take end condition's value of all beams as 1.

streams (Pin 3)

result file container allowed to be kept open to cache data.

data_sources (Pin 4)

result file path container, used if no streams are set.

manufacture (Pin 5)

  • Required: Yes
  • Expected type(s): bool

Manufacturing processus:hot finished if TRUE or cold formed if FALSE. Default value : hot finished.

partial_factor (Pin 6)

  • Required: Yes
  • Expected type(s): double

partial safety factor for resistance of members to instability assessed by member checks. Default value: 1.

mesh (Pin 7)

Mesh containing beam's properties defined by user

axial_force (Pin 8)

Fields Container of axial force defined by user

fabrication_type (Pin 12)

  • Required: Yes
  • Expected type(s): bool

If there is beam I in the structure, please define its fabrication type. True: Rolled section, False: Welded section

Outputs

This table lists the output pins for this operator. Output pins provide the results of the operator's computation and can be connected to inputs of other operators or retrieved for further processing. Each output is detailed in the sections that follow the table.

Pin number Name Expected type(s)
0 buckling_resistance_compression_yy fields_container
1 buckling_resistance_compression_zz fields_container

buckling_resistance_compression_yy (Pin 0)

Fields Container of buckling resistance factor on axis y-y in case of compression. These factors should be less than 1 and positive.

buckling_resistance_compression_zz (Pin 1)

Fields Container of buckling resistance factor on axis z-z in case of compression. These factors should be less than 1 and positive.

Configurations

This operator supports configuration options that modify its behavior.

mutex

  • Expected type(s): bool
  • Default value: false

If this option is set to true, the shared memory is prevented from being simultaneously accessed by multiple threads.

Scripting

This operator can be accessed through scripting interfaces using these identifiers.

Category: result

Plugin: core

Scripting name: members_in_compression_not_certified

Full name: result.members_in_compression_not_certified

Internal name: members_in_compression_not_certified

License: any_dpf_supported_increments

Examples

These examples demonstrate how to use this operator in different programming environments. Each example shows how to instantiate the operator, connect the required inputs, and retrieve the output.

C++
#include "dpf_api.h"

ansys::dpf::Operator op("members_in_compression_not_certified"); // operator instantiation
op.connect(0, my_time_scoping);
op.connect(1, my_field_yield_strength);
op.connect(2, my_field_end_condition);
op.connect(3, my_streams);
op.connect(4, my_data_sources);
op.connect(5, my_manufacture);
op.connect(6, my_partial_factor);
op.connect(7, my_mesh);
op.connect(8, my_axial_force);
op.connect(12, my_fabrication_type);
ansys::dpf::FieldsContainer my_buckling_resistance_compression_yy = op.getOutput<ansys::dpf::FieldsContainer>(0);
ansys::dpf::FieldsContainer my_buckling_resistance_compression_zz = op.getOutput<ansys::dpf::FieldsContainer>(1);
CPython
import ansys.dpf.core as dpf

op = dpf.operators.result.members_in_compression_not_certified() # operator instantiation
op.inputs.time_scoping.connect(my_time_scoping)
op.inputs.field_yield_strength.connect(my_field_yield_strength)
op.inputs.field_end_condition.connect(my_field_end_condition)
op.inputs.streams.connect(my_streams)
op.inputs.data_sources.connect(my_data_sources)
op.inputs.manufacture.connect(my_manufacture)
op.inputs.partial_factor.connect(my_partial_factor)
op.inputs.mesh.connect(my_mesh)
op.inputs.axial_force.connect(my_axial_force)
op.inputs.fabrication_type.connect(my_fabrication_type)
my_buckling_resistance_compression_yy = op.outputs.buckling_resistance_compression_yy()
my_buckling_resistance_compression_zz = op.outputs.buckling_resistance_compression_zz()
IPython
import mech_dpf
import Ans.DataProcessing as dpf

op = dpf.operators.result.members_in_compression_not_certified() # operator instantiation
op.inputs.time_scoping.Connect(my_time_scoping)
op.inputs.field_yield_strength.Connect(my_field_yield_strength)
op.inputs.field_end_condition.Connect(my_field_end_condition)
op.inputs.streams.Connect(my_streams)
op.inputs.data_sources.Connect(my_data_sources)
op.inputs.manufacture.Connect(my_manufacture)
op.inputs.partial_factor.Connect(my_partial_factor)
op.inputs.mesh.Connect(my_mesh)
op.inputs.axial_force.Connect(my_axial_force)
op.inputs.fabrication_type.Connect(my_fabrication_type)
my_buckling_resistance_compression_yy = op.outputs.buckling_resistance_compression_yy.GetData()
my_buckling_resistance_compression_zz = op.outputs.buckling_resistance_compression_zz.GetData()

Changelog

  • Version 0.0.0: Initial release.