Description

XTRACT processing: in the same way as in Sound SAS, this operator chains a denoising step, followed by a tonal extraction step and then a transient extraction step. It returns the individual signals processed at each step, as well as the remainder.

Inputs

Input Name Expected type(s) Description
Pin 0
Required
input_signal fields_container, field Signal(s) on which to apply the XTRACT processing, as a field or fields_container.
Pin 1
Required
parameters_denoiser generic_data_container Structure that contains the parameters of the denoising step:

* Noise levels (Field): level vs frequency of the noise.

This structure is of type Xtract_denoiser_parameters (see this class for more details).
Pin 2
Required
parameters_tonal generic_data_container Structure that contains the parameters of the tonal extraction step:

* Nfft (int) in number of samples
* Regularity setting (float) in percent
* Maximum slope (float) in dB/Hz
* Minimum duration (float) in seconds
* Intertonal gap (float) in Hz
* Local emergence (float) in dB

This structure is of type Xtract_tonal_parameters (see this class for more details).
Pin 3
Required
parameters_transient generic_data_container Structure that contains the parameters of the transient extraction step:

* Lower threshold (float), between 0 and 100 percent
* Upper threshold (float), between 0 and 100 percent

This structure is of type Xtract_transient_parameters (see this class for more details).

Outputs

Output Name Expected type(s) Description
Pin 0 noise_signal fields_container, field Noise signal: signal that contains the noise component, as a field or fields_container (depending on the input).
Pin 1 tonal_signal fields_container, field Tonal signal: signal that contains the tonal components, as a field or fields_container (depending on the input).
Pin 2 transient_signal fields_container, field Tonal signal: signal that contains the transient components, as a field or fields_container (depending on the input).
Pin 3 remainder_signal fields_container, field Remainder: signal that contains everything that has not been classified as noise, tonal or transient signals, as a field or fields_container (depending on the input).

Configurations

Name Expected type(s) Default value Description
mutex bool false If this option is set to true, the shared memory is prevented from being simultaneously accessed by multiple threads.

Scripting

Category: sound

Plugin: sound

Scripting name: None

Full name: None

Internal name: xtract

License: avrxp_snd_level1

Changelog

  • Version 0.0.0: Initial release.